Vertiv has introduced the Vertiv Trinergy uninterruptible power supply (UPS) engineered to handle the fluctuating load demands of data centres, and Vertiv PowerNexus, an integrated solution that provides space-saving close coupling of the UPS and system switchgear.

Vertiv Trinergy UPS is available globally in 1 500, 2 000 and 2 500 kVA capacities.

Vertiv calculates that Vertiv Trinergy exceeds Tier IV data centre power chain expected availability, with 99,9999998% projected uptime. The system boosts resilience with extended backup time configurations and its innovative self-isolating core design, with modular architecture that features 500kW physically segregated cores. Each core includes the components of an online UPS: inverter, rectifier, booster/charger, and dedicated, segregated controls, allowing each core to operate independently providing reliable uninterrupted power delivery even during maintenance.

Vertiv Trinergy scales the concept of modularity up to all levels of the UPS architecture. Building blocks can be combined to fit different deployment types, achieving considerable space savings with its compact footprint. It streamlines power distribution through a single connection point, cutting down the necessity for numerous cables, flanges, bus ducts, and switchgear connections for UPS outputs.

Vertiv Trinergy footprint is maximised when integrated with Vertiv PowerBoard Switchgear as part of the new Vertiv PowerNexus solution, close coupled into a single block connected by internal busbars. This integration also reduces cabling materials, installation time, and installation labour costs.  The Vertiv PowerNexus is also available integrated onsite, as a power skid or integrated into an enclosure, providing flexibility to meet specific site needs. Vertiv PowerNexus integration is completed at the factory, saving installation time at the site. The integrated Vertiv™ EPMS (energy and power monitoring system) with onboard energy monitoring makes the system safer, more reliable and more operable out of the box by increasing visibility and reducing the number of interconnections.

Vertiv Trinergy delivers a double conversion efficiency of up to 97,1%, which increases up to 99% with the Dynamic Online mode. It can provide additional energy saving, as well as cost saving and revenue generation, by leveraging the Dynamic Grid Support feature, which allows the UPS to participate in demand management and other grid services, where available.

With its improved continuous duty booster operation, the UPS is capable of running from a DC source, even at full load, for an indefinite amount of time.

The UPS is also compatible with Vertiv DynaFlex Battery Energy Storage System (BESS).